Class Description

Parent class supporting relationships to IEC wind turbines type 3 generator models of IEC type 3A and 3B.

Attributes

Name Type Description
dipmax PU Maximum active current ramp rate (dipmax). It is a project-dependent parameter.
diqmax PU Maximum reactive current ramp rate (diqmax). It is a project-dependent parameter.
xs PU Electromagnetic transient reactance (xS). It is a type-dependent parameter.

Relationships

Inherits from

Descendant classes

Leaf/Root class

IsLeaf IsRoot
False False

Associations

Source Class Cardinality Source Target Class Cardinality Target Source Name Source Assoc. Description Target Name Target Assoc. Description
WindGenType3IEC 0..1 WindTurbineType3IEC 0..1 WindGenType3IEC Wind generator type 3 model associated with this wind turbine type 3 model. WindTurbineType3IEC Wind turbine type 3 model with which this wind generator type 3 is associated.