Relationship between unit efficiency as percentage and unit output active power for a given net head in meters. The relationship between efficiency, discharge, head, and power output is expressed as follows: E =KP/HQ
where: E is the efficiency, as a percentage; P is the active power; H is the height; Q is the discharge, volume/time unit; K is a constant.
For example, a curve instance for a given net head could show efficiency (Y-axis) versus active power output (X-axis) or versus discharge on the X-axis.

Attributes

None

Relationships

Inherits from

Descendant classes

  • No descendant classes

Leaf/Root class

IsLeaf IsRoot
False False

Associations

Source Class Cardinality Source Target Class Cardinality Target Source Name Source Assoc. Description Target Name Target Assoc. Description
HydroGeneratingEfficiencyCurve 0..* HydroGeneratingUnit 1 HydroGeneratingEfficiencyCurves A hydro generating unit has an efficiency curve. HydroGeneratingUnit A hydro generating unit has an efficiency curve.