Class Description
Cross compound turbine governor. Unlike tandem compound units, cross compound units are not on the same shaft.
Attributes
Name | Type | Description |
---|---|---|
dhp | PU | HP damping factor (Dhp). Typical value = 0. |
dlp | PU | LP damping factor (Dlp). Typical value = 0. |
fhp | PU | Fraction of HP power ahead of reheater (Fhp). Typical value = 0,3. |
flp | PU | Fraction of LP power ahead of reheater (Flp). Typical value = 0,7. |
mwbase | ActivePower | Base for power values (MWbase) (> 0). Unit = MW. |
pmaxhp | PU | Maximum HP value position (Pmaxhp). Typical value = 1. |
pmaxlp | PU | Maximum LP value position (Pmaxlp). Typical value = 1. |
rhp | PU | HP governor droop (Rhp) (> 0). Typical value = 0,05. |
rlp | PU | LP governor droop (Rlp) (> 0). Typical value = 0,05. |
t1hp | Seconds | HP governor time constant (T1hp) (>= 0). Typical value = 0,1. |
t1lp | Seconds | LP governor time constant (T1lp) (>= 0). Typical value = 0,1. |
t3hp | Seconds | HP turbine time constant (T3hp) (>= 0). Typical value = 0,1. |
t3lp | Seconds | LP turbine time constant (T3lp) (>= 0). Typical value = 0,1. |
t4hp | Seconds | HP turbine time constant (T4hp) (>= 0). Typical value = 0,1. |
t4lp | Seconds | LP turbine time constant (T4lp) (>= 0). Typical value = 0,1. |
t5hp | Seconds | HP reheater time constant (T5hp) (>= 0). Typical value = 10. |
t5lp | Seconds | LP reheater time constant (T5lp) (>= 0). Typical value = 10. |
Relationships
Inherits from
Descendant classes
- No descendant classes
Leaf/Root class
IsLeaf | IsRoot |
---|---|
False | False |
Associations