Class Description
Double derivative hydro governor and turbine.
Attributes
Name | Type | Description |
---|---|---|
pgv4 | PU | Nonlinear gain point 4, PU power (Pgv4). Typical value = 0. |
pgv5 | PU | Nonlinear gain point 5, PU power (Pgv5). Typical value = 0. |
pgv6 | PU | Nonlinear gain point 6, PU power (Pgv6). Typical value = 0. |
pmax | PU | Maximum gate opening, PU of MWbase (Pmax) (> GovHydroDD.pmin). Typical value = 1. |
pmin | PU | Minimum gate opening, PU of MWbase (Pmin) (> GovHydroDD.pmax). Typical value = 0. |
r | PU | Steady state droop (R). Typical value = 0,05. |
td | Seconds | Input filter time constant (Td) (>= 0). If = 0, block is bypassed. Typical value = 0. |
tf | Seconds | Washout time constant (Tf) (>= 0). Typical value = 0,1. |
tp | Seconds | Gate servo time constant (Tp) (>= 0). If = 0, block is bypassed. Typical value = 0,35. |
tt | Seconds | Power feedback time constant (Tt) (>= 0). If = 0, block is bypassed. Typical value = 0,02. |
tturb | Seconds | Turbine time constant (Tturb) (>= 0). See parameter detail 3. Typical value = 0,8. |
velcl | Float | Maximum gate closing velocity (Velcl). Unit = PU / s. Typical value = -0,14. |
velop | Float | Maximum gate opening velocity (Velop). Unit = PU / s. Typical value = 0,09. |
aturb | PU | Turbine numerator multiplier (Aturb) (see parameter detail 3). Typical value = -1. |
bturb | PU | Turbine denominator multiplier (Bturb) (see parameter detail 3). Typical value = 0,5. |
db1 | Frequency | Intentional dead-band width (db1). Unit = Hz. Typical value = 0. |
db2 | ActivePower | Unintentional dead-band (db2). Unit = MW. Typical value = 0. |
eps | Frequency | Intentional db hysteresis (eps). Unit = Hz. Typical value = 0. |
gmax | PU | Maximum gate opening (Gmax) (> GovHydroDD.gmin). Typical value = 0. |
gmin | PU | Minimum gate opening (Gmin) (< GovHydroDD.gmax). Typical value = 0. |
gv1 | PU | Nonlinear gain point 1, PU gv (Gv1). Typical value = 0. |
gv2 | PU | Nonlinear gain point 2, PU gv (Gv2). Typical value = 0. |
gv3 | PU | Nonlinear gain point 3, PU gv (Gv3). Typical value = 0. |
gv4 | PU | Nonlinear gain point 4, PU gv (Gv4). Typical value = 0. |
gv5 | PU | Nonlinear gain point 5, PU gv (Gv5). Typical value = 0. |
gv6 | PU | Nonlinear gain point 6, PU gv (Gv6). Typical value = 0. |
inputSignal | Boolean | Input signal switch (Flag). |
true = Pe input is used | ||
false = feedback is received from CV. | ||
Flag is normally dependent on Tt. If Tt is zero, Flag is set to false. If Tt is not zero, Flag is set to true. | ||
Typical value = true. | ||
k1 | PU | Single derivative gain (K1). Typical value = 3,6. |
k2 | PU | Double derivative gain (K2). Typical value = 0,2. |
kg | PU | Gate servo gain (Kg). Typical value = 3. |
ki | PU | Integral gain (Ki). Typical value = 1. |
mwbase | ActivePower | Base for power values (MWbase) (>0). Unit = MW. |
pgv1 | PU | Nonlinear gain point 1, PU power (Pgv1). Typical value = 0. |
pgv2 | PU | Nonlinear gain point 2, PU power (Pgv2). Typical value = 0. |
pgv3 | PU | Nonlinear gain point 3, PU power (Pgv3). Typical value = 0. |
Relationships
Inherits from
Descendant classes
- No descendant classes
Leaf/Root class
IsLeaf | IsRoot |
---|---|
False | False |
Associations
None